مرحبا بكم في مدونتنا

نحن نشارك المعرفة في المجالات التي تبهرنا أكثر
click

E-1 Angled Keratome Blade:Advanced Sapphire Solution for Corneal Surgeries

بواسطة JM Surgicals December 11th, 2024 3 مشاهدات

Abstract

The E-1 Angled Keratome Blade, crafted from high-purity sapphire, is specifically designed for corneal incisions. This study evaluates its precision, tissue damage control, and postoperative recovery benefits through clinical data analysis. Compared to traditional metal blades, the E-1 blade demonstrates significant performance improvements, particularly in minimizing tissue trauma and expediting recovery.

 
1.Introduction

Corneal incisions are a crucial aspect of ophthalmic surgery, directly influencing postoperative vision restoration. Traditional metal blades, while functional, often lack optimal precision and may cause higher tissue damage. The E-1 Angled Keratome Blade has emerged as a preferred tool for corneal incisions due to its superior sharpness and durability.

 
2.Materials and Methods

2.1 Study Design

Group

Number of Patients

Surgery Type

Blade Type

Experimental Group

15

Cataract Surgery, Refractive Surgery

E-1 Angled Keratome Blade

Control Group

15

Cataract Surgery, Refractive Surgery

Traditional Steel Blade

2.2 Data Collection Indicators

  1. Smoothness of incision edges (microscopic observation)
  2. Postoperative inflammation (corneal edema score)
  3. Average healing time (days)
  4. Complication rate (%)
  5. Surgeon feedback (survey)

 
3.Results Analysis

Consolidated Data Table

Indicator

Experimental Group (E-1 Blade)

Control Group (Traditional Blade)

Incision edge smoothness (0-10)

9.8

8.5

Post-op edema score (Day 1, 0-10)

1.2

3.1

Post-op edema score (Day 7, 0-10)

0.3

1.0

Average healing time (days)

4.3

6.7

Complication rate (%)

0

6.7

Surgeon satisfaction (0-10)

9.6

8.2


4.Conclusion

The data indicate that the E-1 Angled Keratome Blade outperforms traditional metal blades in precision, minimizing tissue damage, and reducing postoperative recovery time. Its exceptional surgical performance and positive surgeon feedback suggest that the E-1 blade is a highly effective tool for corneal incision surgeries.

 

Note: The E-1 Angled Keratome Blade is manufactured by Jingming Science & Technology Co., Ltd Shanghai. For more details, visit the The E-1 Angled Keratome Blade.

Surgical Outcomes Related to Blade Maintenance and Care
سابق
Surgical Outcomes Related to Blade Maintenance and Care
اقرأ أكثر
E-2 Angled Crescent Blade for Cataract and Corneal Surgery | Precision Ophthalmic Tool
التالي
E-2 Angled Crescent Blade for Cataract and Corneal Surgery | Precision Ophthalmic Tool
اقرأ أكثر
نحن نستخدم ملفات تعريف الارتباط لتحسين تجربتك عبر الإنترنت. من خلال الاستمرار في تصفح هذا الموقع، فإنك توافق على استخدامنا ملفات تعريف الارتباط.